Oct, 1, 2023

Vol.30 No.2, pp. 84-88


Review

  • Korean Journal of Biological Psychiatry
  • Volume 7(2); 2000
  • Article

Review

Korean Journal of Biological Psychiatry 2000;7(2):180-5. Published online: Feb, 1, 2000

Comparison of Global Field Power Measurement and Conventional Method in Multi-channel Auditory Event Related Potential P300 Determination

  • Yang-Whan Jeon, MD; and Sang-Ick Han, MD
    Department of Neuropsychiatry, Our Lady of Mercy Hospital, The Catholic University of Korea, Inchon, Korea
Abstract

Objective:The present study was designed to compare Global Field Power Measurement and conventional method in P300 determination.

Method:The subjects were composed of patients(N=20) with schizophrenia by DSM-IV and normal controls(N=20). The auditory event related potential P300 was measured by “oddball paradigm”. P300 components were determined by Global Field Power Measurement and conventional method at 5 electrodes(Fz, Cz, Pz, T3, T4).

Results:P300 amplitudes of patients were smaller than those of controls across all electrodes and in both methods, but there was no differential power in P300 determination between two methods. Asymmetry of auditory event-related potential P300 was not shown between patients with schizophrenia and normal controls.

Conclusion:It is implicated that it depends on clinical situations and research purposes what method of P300 determination will be more appropriate for patients with schizophernia.

Keywords 정신분열병;P300;전부위장력측정법;전통적 방법;비대칭성.